Brand
ABBNumber of Poles
1
Product Type
Miniature Circuit Breaker
Current Rating
6A
Tripping Characteristics
Type C
Rated AC Voltage
253V ac
Rated DC Voltage
72V dc
Breaking Capacity
6kA
Mount Type
DIN Rail
Range
System Pro M Compact
Series
System Pro M Compact
Terminal Type
Screw
IP Rating
IP40, IP20
Height
88mm
Depth
69mm
Standards/Approvals
IEC/EN 60947-2, IEC/EN 60898-1
Width
17.5mm
Tripping Mechanism
Thermal
Country of Origin
Germany
Product Details
Safeguard your appliances from electrical faults with this MCB from ABB. It features a delayed thermal tripping system for overload protection and an electromagnetic tripping mechanism to prevent damage from short circuit faults. With maximum operating voltages of 253V on AC circuits and 72V on DC networks, the device is designed for low-voltage applications. As it has type-C characteristics, it will trip at 5 to 10 times its 6A rated current, making it suitable for handling inductive loads with a high chance of short circuits.
The breaking capacity of a circuit breaker is the amount of current that it can interrupt without suffering damage. This unit has a breaking capacity of 6kA, so you can use it in settings prone to high current surges.
Stock information temporarily unavailable.
€ 19.24
€ 19.24 Each (Exc. VAT)
1
€ 19.24
€ 19.24 Each (Exc. VAT)
Stock information temporarily unavailable.
1
Technical Documents
Specifications
Brand
ABBNumber of Poles
1
Product Type
Miniature Circuit Breaker
Current Rating
6A
Tripping Characteristics
Type C
Rated AC Voltage
253V ac
Rated DC Voltage
72V dc
Breaking Capacity
6kA
Mount Type
DIN Rail
Range
System Pro M Compact
Series
System Pro M Compact
Terminal Type
Screw
IP Rating
IP40, IP20
Height
88mm
Depth
69mm
Standards/Approvals
IEC/EN 60947-2, IEC/EN 60898-1
Width
17.5mm
Tripping Mechanism
Thermal
Country of Origin
Germany
Product Details
Safeguard your appliances from electrical faults with this MCB from ABB. It features a delayed thermal tripping system for overload protection and an electromagnetic tripping mechanism to prevent damage from short circuit faults. With maximum operating voltages of 253V on AC circuits and 72V on DC networks, the device is designed for low-voltage applications. As it has type-C characteristics, it will trip at 5 to 10 times its 6A rated current, making it suitable for handling inductive loads with a high chance of short circuits.
The breaking capacity of a circuit breaker is the amount of current that it can interrupt without suffering damage. This unit has a breaking capacity of 6kA, so you can use it in settings prone to high current surges.