Schneider Electric LP2K Reversing Contactor, 24 V dc Coil, 3-Pole, 6 A, 3 kW 24 V, 3 NO, 690V

Technical Document
Specifications
Brand
Schneider ElectricCoil Voltage
24 V dc
Product Type
Reversing Contactor
Number of Poles
3
Contact Voltage
690V
Contact Current
6A
Series
LP2K
Power Rating
3kW
Mount Type
DIN Rail
Function
Reversing
Normal State Configuration
3 NO
Number of Auxiliary Contacts
1
Auxiliary Contact Configuration
1 NO
Terminal Type
Screw
Control Circuit Voltage Uc
24 V
Operational Current Ie
6A
Minimum Operating Temperature
-25°C
Contactor Application
Resistive Load, Motor Control
Maximum Operating Temperature
50°C
Width
90 mm
Depth
57mm
Length
58mm
Standards/Approvals
CCC, UL, RoHS, IEC, EAC, CSA
Better World Product
Yes
Pole and Throw Configuration
3
Country of Origin
France
Product details
Schneider Electric LP2K TeSys K Miniature Reversing Contactors
TeSys K Miniature Reversing Contactors from Schneider Electric combine long mechanical and electrical life to offer a high reliable contactor. The range has been designed for integration in control systems and for inductive motor applications. The TeSys K contactors offer quick simple setup while maintaining compliance with international standards. A special armature structure design allows all devices in the range to have the same physical size and panel footprint for convenience.
Features and Benefits
Built-in auxiliary contacts for added switching capability
Screw connections: IP20 finger-safe terminals with both North American and International terminal markings
Can be panel mounted with screws or DIN Rail mounted
Easily installed accessories
Instantaneous auxiliary contact
Flexible control circuit to suit a wide range of applications
High-fault short circuit current ratings provide the flexibility to select any component
What does the utilisation category AC1 and AC3 mean for the TeSys contactors?
Contactor utilisation categories define the current making and breaking values, based on the type of load to be controlled and the operating cycle conditions.
AC-1: This applies to all AC devices with a power factor of at least 0.95. Example of use: resistive load, heating, distribution.
AC-3: This applies to squirrel cage motors where breaking occurs while the motor is running.
Example of use: all squirrel cage motors, lifts, escalators, conveyors, bucket elevators, compressors, pumps, mixers, air conditioning units.
Are the TeSys K contactors suitable for applications in AC4 usage?
The LC2K series is suitable up to a maximum of 440 V ac in category AC4.
Is the TeSys K range a double break pole type contactor?
Yes the TeSys K range uses linear translation movement that provides double breaking of the poles.
Stock information temporarily unavailable.
€ 108.62
€ 108.62 Each (Exc. VAT)
1
€ 108.62
€ 108.62 Each (Exc. VAT)
Stock information temporarily unavailable.
1
Technical Document
Specifications
Brand
Schneider ElectricCoil Voltage
24 V dc
Product Type
Reversing Contactor
Number of Poles
3
Contact Voltage
690V
Contact Current
6A
Series
LP2K
Power Rating
3kW
Mount Type
DIN Rail
Function
Reversing
Normal State Configuration
3 NO
Number of Auxiliary Contacts
1
Auxiliary Contact Configuration
1 NO
Terminal Type
Screw
Control Circuit Voltage Uc
24 V
Operational Current Ie
6A
Minimum Operating Temperature
-25°C
Contactor Application
Resistive Load, Motor Control
Maximum Operating Temperature
50°C
Width
90 mm
Depth
57mm
Length
58mm
Standards/Approvals
CCC, UL, RoHS, IEC, EAC, CSA
Better World Product
Yes
Pole and Throw Configuration
3
Country of Origin
France
Product details
Schneider Electric LP2K TeSys K Miniature Reversing Contactors
TeSys K Miniature Reversing Contactors from Schneider Electric combine long mechanical and electrical life to offer a high reliable contactor. The range has been designed for integration in control systems and for inductive motor applications. The TeSys K contactors offer quick simple setup while maintaining compliance with international standards. A special armature structure design allows all devices in the range to have the same physical size and panel footprint for convenience.
Features and Benefits
Built-in auxiliary contacts for added switching capability
Screw connections: IP20 finger-safe terminals with both North American and International terminal markings
Can be panel mounted with screws or DIN Rail mounted
Easily installed accessories
Instantaneous auxiliary contact
Flexible control circuit to suit a wide range of applications
High-fault short circuit current ratings provide the flexibility to select any component
What does the utilisation category AC1 and AC3 mean for the TeSys contactors?
Contactor utilisation categories define the current making and breaking values, based on the type of load to be controlled and the operating cycle conditions.
AC-1: This applies to all AC devices with a power factor of at least 0.95. Example of use: resistive load, heating, distribution.
AC-3: This applies to squirrel cage motors where breaking occurs while the motor is running.
Example of use: all squirrel cage motors, lifts, escalators, conveyors, bucket elevators, compressors, pumps, mixers, air conditioning units.
Are the TeSys K contactors suitable for applications in AC4 usage?
The LC2K series is suitable up to a maximum of 440 V ac in category AC4.
Is the TeSys K range a double break pole type contactor?
Yes the TeSys K range uses linear translation movement that provides double breaking of the poles.