Technical Documents
Specifications
Brand
HoneywellActuator Type
Roller Plunger
Product Type
Limit Switch
Contact Configuration
SPDT
IP Rating
IP66
Housing Material
Die Cast Zinc Epoxy Coated
Contact Type
Snap Action
Switching Current
6A
Terminal Type
Screw
Series
GLC
Minimum Operating Temperature
-40°C
Switching DC Voltage
250V dc
Switching AC Voltage
240V ac
Maximum Operating Temperature
85°C
Depth
26.35mm
Length
68.5mm
Standards/Approvals
CCC, UL, CSA, CE
Width
30.5mm
Hazardous Area Certification
No
Conduit Entry
PG13.5
Mechanical Life
10000000Cycles
Operating Force
16N
Country of Origin
United Kingdom
Product Details
This limit switch provides precise position detection for industrial automation and control systems, using a roller plunger actuator to convert mechanical movement into an electrical signal. It is suited to demanding environments where a compact, enclosed switching device is required and supports standard conduit attachment for wiring.
It employs a single-pole double-throw snap-action contact that switches rapidly between circuits, providing a clear changeover suitable for control logic and interlock circuits.
The housing is formed from die-cast zinc, offering mechanical strength and resistance to impact in industrial settings.
The body is designed for space-conscious installations with a low profile and narrow footprint to fit confined mounting locations.
It carries recognised safety approvals, indicating conformity with multiple international electrical and safety standards.
The actuator requires an operating force of 16 N to engage the switching mechanism.
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
UL/ UL listed for Canada
GLC and GLD limit switches are not safety devices. They should be not used as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of product failure.
Stock information temporarily unavailable.
€ 158.85
€ 158.85 Each (Exc. VAT)
1
€ 158.85
€ 158.85 Each (Exc. VAT)
Stock information temporarily unavailable.
1
Technical Documents
Specifications
Brand
HoneywellActuator Type
Roller Plunger
Product Type
Limit Switch
Contact Configuration
SPDT
IP Rating
IP66
Housing Material
Die Cast Zinc Epoxy Coated
Contact Type
Snap Action
Switching Current
6A
Terminal Type
Screw
Series
GLC
Minimum Operating Temperature
-40°C
Switching DC Voltage
250V dc
Switching AC Voltage
240V ac
Maximum Operating Temperature
85°C
Depth
26.35mm
Length
68.5mm
Standards/Approvals
CCC, UL, CSA, CE
Width
30.5mm
Hazardous Area Certification
No
Conduit Entry
PG13.5
Mechanical Life
10000000Cycles
Operating Force
16N
Country of Origin
United Kingdom
Product Details
This limit switch provides precise position detection for industrial automation and control systems, using a roller plunger actuator to convert mechanical movement into an electrical signal. It is suited to demanding environments where a compact, enclosed switching device is required and supports standard conduit attachment for wiring.
It employs a single-pole double-throw snap-action contact that switches rapidly between circuits, providing a clear changeover suitable for control logic and interlock circuits.
The housing is formed from die-cast zinc, offering mechanical strength and resistance to impact in industrial settings.
The body is designed for space-conscious installations with a low profile and narrow footprint to fit confined mounting locations.
It carries recognised safety approvals, indicating conformity with multiple international electrical and safety standards.
The actuator requires an operating force of 16 N to engage the switching mechanism.
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
UL/ UL listed for Canada