Technical Documents
Specifications
Brand
ABBProduct Type
Safety Controller Key
Series
IDFIX-R
Mount Type
Surface
Standards/Approvals
CSA, CE
Country of Origin
Estonia
Product Details
Pluto from ABB is an "All-Master" safety PLC concept, which simplifies the design of safety systems and achieves the highest safety category 4 according to EN 954-1. All Pluto's are Master units and can see the other Pluto's inputs, outputs and global memories. This enables the Pluto to evaluate the information from the other Pluto's and then take decisions concerning its own safety devices. The Gateway units are available for several different bus systems, i.e. Profibus, CanOpen, Devicenet and Ethernet. Of Pluto's inputs (the smallest unit has 16 I/O), thus can be configured as either inputs or outputs. In the Pluto family by ABB most modules have dual safety outputs - potential free or PNP types. In a two-wire bus system up to 32 Pluto units can be safely connected and communicate with a superior system via a Gateway or HMI displays. Therefore within a maximum extended system 1472 I/O's can be connected. Also all input components may be connected in series for even more complexity and optimisation.
The IDFIX device (733-4824) is connected between the input terminals ID and 0V (also note that the IDFIX device is not required when using a single Pluto, however the absense of an IDFIX requires to be stated when programming the Pluto device.)
TUV, FS, CSA
Stock information temporarily unavailable.
€ 19.42
€ 19.42 Each (Exc. VAT)
1
€ 19.42
€ 19.42 Each (Exc. VAT)
Stock information temporarily unavailable.
1
| Quantity | Unit price |
|---|---|
| 1 - 4 | € 19.42 |
| 5 - 9 | € 18.46 |
| 10 - 24 | € 17.48 |
| 25 - 49 | € 16.53 |
| 50+ | € 15.54 |
Technical Documents
Specifications
Brand
ABBProduct Type
Safety Controller Key
Series
IDFIX-R
Mount Type
Surface
Standards/Approvals
CSA, CE
Country of Origin
Estonia
Product Details
Pluto from ABB is an "All-Master" safety PLC concept, which simplifies the design of safety systems and achieves the highest safety category 4 according to EN 954-1. All Pluto's are Master units and can see the other Pluto's inputs, outputs and global memories. This enables the Pluto to evaluate the information from the other Pluto's and then take decisions concerning its own safety devices. The Gateway units are available for several different bus systems, i.e. Profibus, CanOpen, Devicenet and Ethernet. Of Pluto's inputs (the smallest unit has 16 I/O), thus can be configured as either inputs or outputs. In the Pluto family by ABB most modules have dual safety outputs - potential free or PNP types. In a two-wire bus system up to 32 Pluto units can be safely connected and communicate with a superior system via a Gateway or HMI displays. Therefore within a maximum extended system 1472 I/O's can be connected. Also all input components may be connected in series for even more complexity and optimisation.
The IDFIX device (733-4824) is connected between the input terminals ID and 0V (also note that the IDFIX device is not required when using a single Pluto, however the absense of an IDFIX requires to be stated when programming the Pluto device.)
TUV, FS, CSA