Technical Documents
Specifications
Brand
TDK-LambdaProduct Type
Switching Power Supply
Maximum Output Voltage
19V dc
Number of Outputs
1
Mount Type
Panel
Power
600W
Minimum Operating Temperature
-20°C
SMPS Output Current
21.1A
Maximum Operating Temperature
70°C
Length
198mm
Depth
198mm
Weight
440g
Standards/Approvals
IEC 61000-4-11, FCC-B, EN 55022-B, CE, IEC 61000-4-3 (lv3), IEC 61000-4-4 (lv 3), IEC 61000-4-5 (lv 3,4), IEC 61000-4-6 (lv 3), IEC 61000-4-8 (lv 4), IEC/UL/CSA/EN 62368-1, IEC 61000-4-2 (lv 2,3)
Width
128mm
Efficiency
90%
Maximum Input Voltage
265V ac
Series
CUS600M
Output Current
21.1A
Hazardous Area Certification
No
Minimum Input Voltage
85V ac
Country of Origin
China
Product Details
The TDK-Lambda compact CUS600M is packaged in the industry standard 3x5 footprint and can deliver 600W with forced air or 400W with a 600W peak power with convection cooling. With Medical & ITE certifications, the unit can be used in both Class I & Class II (no ground wire) applications, and meets Class B Conducted and Radiated EMI. A 5V 2A standby voltage, remote on/off, remote sense and a Power Good signal are fitted as standard. Other options, including an internal fan, are available.
Stock information temporarily unavailable.
€ 186.28
€ 186.28 Each (Exc. VAT)
1
€ 186.28
€ 186.28 Each (Exc. VAT)
Stock information temporarily unavailable.
1
| Quantity | Unit price |
|---|---|
| 1 - 4 | € 186.28 |
| 5 - 9 | € 181.44 |
| 10 - 24 | € 176.84 |
| 25 - 49 | € 172.47 |
| 50+ | € 168.32 |
Technical Documents
Specifications
Brand
TDK-LambdaProduct Type
Switching Power Supply
Maximum Output Voltage
19V dc
Number of Outputs
1
Mount Type
Panel
Power
600W
Minimum Operating Temperature
-20°C
SMPS Output Current
21.1A
Maximum Operating Temperature
70°C
Length
198mm
Depth
198mm
Weight
440g
Standards/Approvals
IEC 61000-4-11, FCC-B, EN 55022-B, CE, IEC 61000-4-3 (lv3), IEC 61000-4-4 (lv 3), IEC 61000-4-5 (lv 3,4), IEC 61000-4-6 (lv 3), IEC 61000-4-8 (lv 4), IEC/UL/CSA/EN 62368-1, IEC 61000-4-2 (lv 2,3)
Width
128mm
Efficiency
90%
Maximum Input Voltage
265V ac
Series
CUS600M
Output Current
21.1A
Hazardous Area Certification
No
Minimum Input Voltage
85V ac
Country of Origin
China
Product Details
The TDK-Lambda compact CUS600M is packaged in the industry standard 3x5 footprint and can deliver 600W with forced air or 400W with a 600W peak power with convection cooling. With Medical & ITE certifications, the unit can be used in both Class I & Class II (no ground wire) applications, and meets Class B Conducted and Radiated EMI. A 5V 2A standby voltage, remote on/off, remote sense and a Power Good signal are fitted as standard. Other options, including an internal fan, are available.