PAT Testers
PAT testers, or portable appliance testers, are specialised testing devices that are essential for checking electrical devices for faults in a wide range of working environments. PAT testing equipment will provide a pass or fail for the appliance you are testing immediately, so you know it's safe to use. By using the appropriate type of PAT tester, you can identify potential electrical risks, miti...
Showing 1-20 of 141 products
Seaward
Pass/Fail PAT
-
PAT Tester
Class I, Class II
-
-
Automatic
-
-
-
Type G - British 3-Pin
-
-
PrimeTest 50 UK
Battery
AA
-
-
-
-
-
-
-
55mm
260mm
800g
100 mm
No
-
230V
-
-
-
Seaward
PAT Tester Kit
-
PAT Testing Kit
Class I
-
-
Automatic
Yes
-
-
-
-
-
PrimeTest 250+ Pro Bundle UK
Battery
AA
-
225V ac
-
0°C
-
40°C
-
265mm
-
800g
105 mm
No
-
254V ac
-
-
-
Seaward
Pass/Fail PAT
-
PAT Tester
Class II, Class I
-
-
Automatic
-
-
-
3-Pin (Global)
-
-
PrimeTest 100 UK
Battery
AA
-
-
-
0°C
-
40°C
-
55mm
260mm
800g
100 mm
No
-
230V
-
-
-
Martindale
Pass/Fail PAT
-
PAT Tester
Class II, Class I
-
-
Automatic
-
-
-
-
-
-
HPAT400/2
Battery
AA
-
-
-
-10°C
-
40°C
-
210mm
90mm
700g
54 mm
BS EN 61010-1
-
-
-
-
-
Seaward
Advanced PAT
-
PAT Tester
Class I
-
-
Automatic
Yes
-
-
-
-
-
PrimeTest 250+ UK
Battery
AA
-
225V ac
-
0°C
-
40°C
-
265mm
-
800g
105 mm
No
-
254V ac
-
-
-
Seaward
Computerised PAT
-
PAT Tester
Class I
-
-
Automatic
Yes
Yes
-
-
-
-
Apollo 500+
Battery, Mains
Rechargeable
-
207V ac
-
-
-
-
-
100mm
230mm
1.5kg
150 mm
RoHS
-
253V ac
-
-
-
Seaward
PAT Tester Kit
-
PAT Testing Kit
Class I
-
-
Automatic
Yes
Yes
-
-
-
-
Apollo 600 + Pro Bundle
Mains, Battery
Rechargeable
-
207V ac
-
-
-
-
-
100mm
230mm
1.5kg
150 mm
RoHS
-
253V ac
-
-
-
Martindale
-
-
PAT Tester
-
-
-
Manual
-
-
-
3-Pin (Global)
-
-
LTDV
Mains
-
-
110V
-
0°C
-
35°C
-
51mm
141mm
-
82 mm
IEC 1010
-
240V
-
-
-
Seaward
Computerised PAT
-
PAT Tester
Class I
-
-
Automatic
Yes
Yes
-
-
-
-
Apollo 600+
Battery, Mains
Rechargeable
-
207V ac
-
-
-
-
-
100mm
230mm
1.5kg
150 mm
RoHS
-
253V ac
-
-
-
Megger
Pass/Fail PAT
-
PAT Tester
Class I, Class II
-
-
-
Yes
Yes
-
3-Pin (Global), BS4343
-
-
PAT410
Mains
-
-
-
-
-10°C
-
50°C
-
210mm
390mm
2.7kg
280 mm
IEC 61010-1
-
230V
-
-
-
Megger
Pass/Fail PAT
-
PAT Tester
Class II, Class I
-
-
-
Yes
Yes
-
3-Pin (Global), BS4343
-
-
PAT420
Mains
-
-
110V
-
-10°C
-
50°C
-
180mm
320mm
4.4kg
255 mm
IEC 61010-1
-
230V
-
-
-
Seaward
Advanced PAT
-
PAT Testing Kit
Class I
-
-
Automatic
Yes
-
-
-
-
-
-
Battery
AA
-
225V ac
-
0°C
-
40°C
-
265mm
-
800g
105 mm
No
-
254V ac
-
-
-
Martindale
Pass/Fail PAT
-
PAT Tester
Class I, Class II
-
-
-
-
-
-
-
-
-
HPAT600/2
Battery
AA
-
-
-
-10°C
-
40°C
-
210mm
90mm
700g
54 mm
BS EN 61010-1
-
1.2V
-
-
-
Megger
Pass/Fail PAT
-
PAT Tester
Class II, Class I
-
-
-
-
-
-
BS1363
-
-
PAT150R-UK
Battery
AA
-
230V ac
-
0°C
-
40°C
-
78mm
203mm
1.3kg
148 mm
IEC 61010-1
-
230V ac
-
-
-
Seaward
PAT Tester Kit
-
PAT Testing Kit
Class I
-
-
Automatic
Yes
Yes
-
-
-
-
Apollo 500 + Pro Bundle
Mains, Battery
Rechargeable
-
207V ac
-
-
-
-
-
100mm
230mm
1.5kg
150 mm
RoHS
-
253V ac
-
-
-
Fluke
Pass/Fail PAT
-
PAT Tester
Class I, Class II
-
-
Manual
-
-
-
3-Pin (Global)
-
-
6200
Mains
-
-
110V
-
0°C
-
40°C
-
100mm
200mm
3kg
275 mm
EN 61010-1
-
230V
-
-
-
Megger
Pass/Fail PAT
-
PAT Tester
Class II, Class I
-
-
-
-
Yes
-
3-Pin (Global)
-
-
PAT320
Mains
-
-
110V ac
-
10°C
-
50°C
-
175mm
320mm
4.5kg
250 mm
IEC 61010-1
-
230V ac
-
-
-
Seaward
Computerised PAT
-
PAT Tester
Class I
-
-
Automatic
Yes
Yes
-
-
-
-
Apollo 400+
Battery, Mains
Rechargeable
-
207V ac
-
-
-
-
-
100mm
230mm
1.5kg
150 mm
RoHS
-
253V ac
-
-
-
Fluke
Pass/Fail PAT
-
PAT Testing Kit
Class I, Class II
-
-
Manual
Yes
-
-
Type G - British 3-Pin
-
-
6200-2
Mains
-
-
4V ac
-
0°C
-
40°C
-
114mm
200mm
3.1kg
275 mm
No
-
240V
-
-
-
Chauvin Arnoux
-
Machine and Electrical Switchboard Testers
-
-
Class I, Class II
Automatic, Manual
-
-
-
Mains
-
CA 6161
Type F - Schuko plug
-
-
-
340 x 405 x 194mm
-
9kg
-
194mm
-
340mm
-
-
-
-
-
3000V
-
-
405mm
40V
...



















