Technical Document
Specifications
Brand
Gossen MetrawattTest Type
Class I, Class II
Testing Method
Automatic, Manual
Download
Yes
Flash Test
Yes
Model Number p
SECULIFE ST
Plug Type
CEE 7/7
Weight
4.5kg
Height
243mm
Length
292mm
Maximum Operating Temperature
+50°C
Maximum Supply Voltage
253V
Width
138mm
Minimum Supply Voltage
103V
Minimum Operating Temperature
0°C
Country of Origin
Germany
Product details
SECULIFE ST tester, VDE 0701-0702, 0751
Ideally suited for performing and documenting measurements at medical devices per DIN VDE 0751 / IEC 62353 and EN 60601 2nd and 3rd edition
Testing of Electrical equipment per DIN VDE 0701-0702
Routine tests, e.g. per EN 61010, EN 60950, EN 60335 etc.
Protective conductor resistance with 200 mA and 10 A test current
Insulation resistance
Earth leakage current
Contact current (device leakage current)
Patient leakage current, AC and DC
Patient auxiliary current
Equivalent leakage current procedure
Direct measurement
Differential current measurement
Up to 10 application parts can be connected (4 mm) and individually assigned to groups
Internal memory for 125 tests
Interfaces: RS 232 port / SecuStore memory adapter (optional)
Supplied with
SECULIFE ST test instrument with 10 + 2 connectors for application parts, probe cable with test probe, plug-on alligator clip for test probes, 3x plug-on quick-connect terminals, 10x conductor patient connection cable 2 mm, 10x Clip-on alligator clip 2 mm, Calibration Certificate per DKD, operating instructions, carrying strap
Stock information temporarily unavailable.
Please check again later.
P.O.A.
1
P.O.A.
1
Technical Document
Specifications
Brand
Gossen MetrawattTest Type
Class I, Class II
Testing Method
Automatic, Manual
Download
Yes
Flash Test
Yes
Model Number p
SECULIFE ST
Plug Type
CEE 7/7
Weight
4.5kg
Height
243mm
Length
292mm
Maximum Operating Temperature
+50°C
Maximum Supply Voltage
253V
Width
138mm
Minimum Supply Voltage
103V
Minimum Operating Temperature
0°C
Country of Origin
Germany
Product details
SECULIFE ST tester, VDE 0701-0702, 0751
Ideally suited for performing and documenting measurements at medical devices per DIN VDE 0751 / IEC 62353 and EN 60601 2nd and 3rd edition
Testing of Electrical equipment per DIN VDE 0701-0702
Routine tests, e.g. per EN 61010, EN 60950, EN 60335 etc.
Protective conductor resistance with 200 mA and 10 A test current
Insulation resistance
Earth leakage current
Contact current (device leakage current)
Patient leakage current, AC and DC
Patient auxiliary current
Equivalent leakage current procedure
Direct measurement
Differential current measurement
Up to 10 application parts can be connected (4 mm) and individually assigned to groups
Internal memory for 125 tests
Interfaces: RS 232 port / SecuStore memory adapter (optional)
Supplied with
SECULIFE ST test instrument with 10 + 2 connectors for application parts, probe cable with test probe, plug-on alligator clip for test probes, 3x plug-on quick-connect terminals, 10x conductor patient connection cable 2 mm, 10x Clip-on alligator clip 2 mm, Calibration Certificate per DKD, operating instructions, carrying strap