RS PRO Type T Thermocouple 1m Length, 2mm Diameter → +350°C

RS Stock No.: 621-2164Brand: RS PRO
brand-logo
View all in Thermocouples

Technical Document

Specifications

Brand

RS Pro

Thermocouple Type

T

Probe Diameter

2mm

Probe Length

1m

Maximum Temperature Sensed

+350°C

Probe Material

Teflon PTFE

Termination Type

Cable

Cable Length

1m

Standards Met

RoHS Compliant

Response Time

0.5 s

Country of Origin

France

Product details

RS Pro IEC PTFE Grounded Welded Tip Wire Thermocoupless

From RS Pro a range of Type J, K, N and T wire type thermocouple temperature sensors that conform to IEC 60584. These thermocouples have a welded grounded junction for a fast response time and leads with a durable PTFE insulation

How does a Thermocouple Work?

A thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect

Welded Grounded Junction

In a welded grounded junction the two thermocouple wires and sheath are welded together to form one junction at the probe tip. These thermocouples have a fast response time because all the thermocouple is making contact with the sheath allowing the heat to transfer easily.

Key Features and Benefits

• Welded grounded junction with fast response
• Conform to IEC 60584 standards
• PTFE insulated leads for for resistance to oils, acid, fluids and good mechanical strength and flexibility

Applications

These grounded junction Type J, K, N and T wire thermocouples are Ideal for test and development applications including test and measurement, temperature mapping and OEM applications

Standards

IEC-BS 4937 60584-2 & IEC-BS 4937 60584-3

You may be interested in

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

€ 23.523

Each (In a Pack of 5) (Exc. VAT)

RS PRO Type T Thermocouple 1m Length, 2mm Diameter → +350°C

€ 23.523

Each (In a Pack of 5) (Exc. VAT)

RS PRO Type T Thermocouple 1m Length, 2mm Diameter → +350°C
Stock information temporarily unavailable.

Buy in bulk

QuantityUnit pricePer Pack
5 - 20€ 23.523€ 117.62
25 - 45€ 22.699€ 113.49
50+€ 21.923€ 109.61
You may be interested in

Technical Document

Specifications

Brand

RS Pro

Thermocouple Type

T

Probe Diameter

2mm

Probe Length

1m

Maximum Temperature Sensed

+350°C

Probe Material

Teflon PTFE

Termination Type

Cable

Cable Length

1m

Standards Met

RoHS Compliant

Response Time

0.5 s

Country of Origin

France

Product details

RS Pro IEC PTFE Grounded Welded Tip Wire Thermocoupless

From RS Pro a range of Type J, K, N and T wire type thermocouple temperature sensors that conform to IEC 60584. These thermocouples have a welded grounded junction for a fast response time and leads with a durable PTFE insulation

How does a Thermocouple Work?

A thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect

Welded Grounded Junction

In a welded grounded junction the two thermocouple wires and sheath are welded together to form one junction at the probe tip. These thermocouples have a fast response time because all the thermocouple is making contact with the sheath allowing the heat to transfer easily.

Key Features and Benefits

• Welded grounded junction with fast response
• Conform to IEC 60584 standards
• PTFE insulated leads for for resistance to oils, acid, fluids and good mechanical strength and flexibility

Applications

These grounded junction Type J, K, N and T wire thermocouples are Ideal for test and development applications including test and measurement, temperature mapping and OEM applications

Standards

IEC-BS 4937 60584-2 & IEC-BS 4937 60584-3