United Automation Fan Speed Controller for Use with AC Fans, 230 V ac, 1A Max, Infinitely Variable

RS Stock No.: 919-6248Brand: United AutomationManufacturers Part No.: VAC2-1/RFI
brand-logo
View all in Fan Speed Controllers

Technical Document

Specifications

For Use With

AC Fans

Speed Settings

Infinitely Variable

Maximum Current

1A

Supply Voltage

230 V ac

Product details

VAC2-1/RFI 1A Fan Speed Controller + RFI Filter

The VAC2-1/RFI is a compact variable phase-angle regulator of open construction and suitable for 230V single-phase operation with mains driven inductive loads, such as induction motors, fans and pumps. An integral choke/capacitor RFI circuit enables the controller to meet current EMC standards for emissions.

Infinitely variable 0-98% output
Maximum RMS on-state current: 1A
Minimum operating current: 100mA
Minimum Set Speed Adjuster
Large triac for inrush protection
Integral RC Snubber
Integral EMC filtering
Peak one cycle surge @ 10mS: 80A
I²t for fusing: 36A²s
Isolation voltage: 2500 Vrms
Maximum recommended unit temperature: +70ºC
Mains supply: 230 Vac ±10% @ 50/60Hz
Single hole fixing

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

€ 40.58

Each (Exc. Vat)

United Automation Fan Speed Controller for Use with AC Fans, 230 V ac, 1A Max, Infinitely Variable

€ 40.58

Each (Exc. Vat)

United Automation Fan Speed Controller for Use with AC Fans, 230 V ac, 1A Max, Infinitely Variable
Stock information temporarily unavailable.

Buy in bulk

QuantityUnit price
1 - 4€ 40.58
5 - 9€ 39.85
10 - 24€ 38.22
25 - 49€ 35.06
50+€ 33.24

Technical Document

Specifications

For Use With

AC Fans

Speed Settings

Infinitely Variable

Maximum Current

1A

Supply Voltage

230 V ac

Product details

VAC2-1/RFI 1A Fan Speed Controller + RFI Filter

The VAC2-1/RFI is a compact variable phase-angle regulator of open construction and suitable for 230V single-phase operation with mains driven inductive loads, such as induction motors, fans and pumps. An integral choke/capacitor RFI circuit enables the controller to meet current EMC standards for emissions.

Infinitely variable 0-98% output
Maximum RMS on-state current: 1A
Minimum operating current: 100mA
Minimum Set Speed Adjuster
Large triac for inrush protection
Integral RC Snubber
Integral EMC filtering
Peak one cycle surge @ 10mS: 80A
I²t for fusing: 36A²s
Isolation voltage: 2500 Vrms
Maximum recommended unit temperature: +70ºC
Mains supply: 230 Vac ±10% @ 50/60Hz
Single hole fixing