Technical Document
Specifications
Brand
Schneider ElectricCoil Voltage
48 V ac
Product Type
Contactor
Number of Poles
3
Contact Voltage
690V
Contact Current
50A
Series
LC1D
Power Rating
22kW
Mount Type
DIN Rail
Function
Motor Control
Normal State Configuration
3 NO
Number of Auxiliary Contacts
2
Auxiliary Contact Configuration
1 NO/1 NC
Terminal Type
Screw Clamp
Control Circuit Voltage Uc
48 V
Operational Current Ie
50A
Minimum Operating Temperature
-5°C
Contactor Application
Motor Control, Resistive Load
Maximum Operating Temperature
60°C
Width
55 mm
Depth
120mm
Length
122mm
Standards/Approvals
EAC, CCC, CSA, IEC, RoHS, UL
Better World Product
Yes
Pole and Throw Configuration
3
Country of Origin
Indonesia
Product details
Schneider Electric TeSys LC1 - D Everlink Contactors
TeSys Contactors from Schneider Electric combine long mechanical and electrical life to offer a high reliable contactor. The TeSys contactors offer quick simple setup while maintaining compliance with international standards.
Features and Benefits
Typically, applications include resistive loads and motor control
Highly reliable
Excellent quality
Easily installed accessories
TeSys contactors fitted with Everlink power terminals, with hexagon socket-head screw.
Allows for a single piece starter assembly with an Everlink breaker (vertical or side by side assembly).
22 → 30 kW motor control, AC3 category at 440 Vac.
Start control from 60 → 80 A for lighting and distribution
What does the utilisation category AC1 and AC3 mean for the TeSys contactors?
Contactor utilisation categories define the current making and breaking values, based on the type of load to be controlled and the operating cycle conditions.
AC-1: This applies to all AC devices with a power factor of at least 0.95. Example of use: resistive load, heating, distribution.
AC-3: This applies to squirrel cage motors where breaking occurs while the motor is running. Example of use: all squirrel cage motors, lifts, escalators, conveyors, bucket elevators, compressors, pumps, mixers, air conditioning units.
What accessories are available?
Auxiliary contact blocks with serrated wiping action
Front mount dust tight auxiliary contact blocks
Pneumatic time delay blocks
Transient voltage surge suppressors
Interface modules and electronic timers
Mechanical latching blocks
Is the TeSys D range a double break pole type contactor?
Yes, the TeSys D range uses linear translation movement that provides double breaking of the poles.
Stock information temporarily unavailable.
€ 219.40
€ 219.40 Each (Exc. VAT)
1
€ 219.40
€ 219.40 Each (Exc. VAT)
Stock information temporarily unavailable.
1
Technical Document
Specifications
Brand
Schneider ElectricCoil Voltage
48 V ac
Product Type
Contactor
Number of Poles
3
Contact Voltage
690V
Contact Current
50A
Series
LC1D
Power Rating
22kW
Mount Type
DIN Rail
Function
Motor Control
Normal State Configuration
3 NO
Number of Auxiliary Contacts
2
Auxiliary Contact Configuration
1 NO/1 NC
Terminal Type
Screw Clamp
Control Circuit Voltage Uc
48 V
Operational Current Ie
50A
Minimum Operating Temperature
-5°C
Contactor Application
Motor Control, Resistive Load
Maximum Operating Temperature
60°C
Width
55 mm
Depth
120mm
Length
122mm
Standards/Approvals
EAC, CCC, CSA, IEC, RoHS, UL
Better World Product
Yes
Pole and Throw Configuration
3
Country of Origin
Indonesia
Product details
Schneider Electric TeSys LC1 - D Everlink Contactors
TeSys Contactors from Schneider Electric combine long mechanical and electrical life to offer a high reliable contactor. The TeSys contactors offer quick simple setup while maintaining compliance with international standards.
Features and Benefits
Typically, applications include resistive loads and motor control
Highly reliable
Excellent quality
Easily installed accessories
TeSys contactors fitted with Everlink power terminals, with hexagon socket-head screw.
Allows for a single piece starter assembly with an Everlink breaker (vertical or side by side assembly).
22 → 30 kW motor control, AC3 category at 440 Vac.
Start control from 60 → 80 A for lighting and distribution
What does the utilisation category AC1 and AC3 mean for the TeSys contactors?
Contactor utilisation categories define the current making and breaking values, based on the type of load to be controlled and the operating cycle conditions.
AC-1: This applies to all AC devices with a power factor of at least 0.95. Example of use: resistive load, heating, distribution.
AC-3: This applies to squirrel cage motors where breaking occurs while the motor is running. Example of use: all squirrel cage motors, lifts, escalators, conveyors, bucket elevators, compressors, pumps, mixers, air conditioning units.
What accessories are available?
Auxiliary contact blocks with serrated wiping action
Front mount dust tight auxiliary contact blocks
Pneumatic time delay blocks
Transient voltage surge suppressors
Interface modules and electronic timers
Mechanical latching blocks
Is the TeSys D range a double break pole type contactor?