Technical Document
Specifications
Brand
DoldSupply Voltage
230V ac
Number of Channels
2
Safety Contacts
2
Function
Emergency Stop
Range
Safemaster
Safety Category ISO 13849-1
4
Safety Category (ISO 13849-1)
4
PL ISO 13849-1
e
PL (ISO 13849-1)
e
SIL IEC 61508
3
SIL (IEC 61508)
3
Series
BD 5987
Width
45mm
Depth
121mm
Performance Level
e
Length
74mm
Country of Origin
Germany
Product details
Emergency stop module, BD5987.02 / 001
Machine emergency stop switches
Monitoring sliding grill guards
SK 4 (with equivalent switching)
Output: 2 N/Os for AC 250 V
1 or 2-channel configuration
Line termination detection on the ON button
Optional: cross-fault detection in the emergency stop control circuit
Optional: automatic on-function when operational voltage is met or system is activated with the
ON button
LED displays for channel 1 and channel 2 and operational mode
Control loop for monitoring external contactors
Protection of humans and machines in accordance with: EC Directive on Machines 89/392/EEC, IEC 204, EN 60204, DIN VDE 0113
Approvals
BG, SUVA, SA (Sweden), UL, CSA
Standards
EN 60204-1 (stop functions), EN 418, prEN574, prEN 954-1
Stock information temporarily unavailable.
Please check again later.
€ 365.69
€ 365.69 Each (Exc. VAT)
1
€ 365.69
€ 365.69 Each (Exc. VAT)
1
Technical Document
Specifications
Brand
DoldSupply Voltage
230V ac
Number of Channels
2
Safety Contacts
2
Function
Emergency Stop
Range
Safemaster
Safety Category ISO 13849-1
4
Safety Category (ISO 13849-1)
4
PL ISO 13849-1
e
PL (ISO 13849-1)
e
SIL IEC 61508
3
SIL (IEC 61508)
3
Series
BD 5987
Width
45mm
Depth
121mm
Performance Level
e
Length
74mm
Country of Origin
Germany
Product details
Emergency stop module, BD5987.02 / 001
Machine emergency stop switches
Monitoring sliding grill guards
SK 4 (with equivalent switching)
Output: 2 N/Os for AC 250 V
1 or 2-channel configuration
Line termination detection on the ON button
Optional: cross-fault detection in the emergency stop control circuit
Optional: automatic on-function when operational voltage is met or system is activated with the
ON button
LED displays for channel 1 and channel 2 and operational mode
Control loop for monitoring external contactors
Protection of humans and machines in accordance with: EC Directive on Machines 89/392/EEC, IEC 204, EN 60204, DIN VDE 0113
Approvals
BG, SUVA, SA (Sweden), UL, CSA
Standards
EN 60204-1 (stop functions), EN 418, prEN574, prEN 954-1