Chauvin Arnoux Cable Detector Cable Tracer, Cable Detection Depth 2.5m, 2.5 m 125 kHz, Maximum Safe Working Voltage 600

RS Stock No.: 800-3802Brand: Chauvin ArnouxManufacturers Part No.: P01141626Distrelec Article No.: 30077270
brand-logo
View all in Cable Tracers & Fuse Finders

Technical Document

Specifications

Display Type

LCD, LCD

Product Type

Cable Detector

Cable Detection Depth

2.5, 2.5m

Meter Type

Cable Tracer

Battery Type

AAA, AAA

Power Source

Battery, Battery

Includes

Adapter, Battery, Carrying Case

Maximum Frequency

125kHz

Maximum Operating Temperature

40°C

Maximum Safe Working Voltage

600V

Standards/Approvals

No

Minimum Operating Temperature

40°C

Minimum Safe Working Voltage

12V

Safety Category Level

CAT III, CAT III

Safety Category Voltage

300, 300V

Country of Origin

Hong Kong

Product details

C.A 6681 LOCAT-N Cable Locator

The CA 6681 cable and metal-pipe detector is ideal for housing renovation, building maintenance and operations after incidents

Electricity:

The C.A 6681 LOCAT-N Cable Locator is simple to use on both current-carrying and non-current-carrying mains circuits. Its digital technology overcomes interference and disturbance signals to provide precise location details. The receiver displays the value of the signal measured, which is also shown on the bar chart or in the form of acoustic signals whose amplitudes vary in proportion to the signal distance.

Identify a fuse, circuit-breaker, etc.
Track a cable in a wall
Determine the location of a cut in the circuit
Locate short-circuits
Locate cable ducts in a house
Detect buried conductors

Plumbing / heating:

Locate pipes (copper, steel)
Track plastic pipes

Telecom:

Cable location
Identification of a pair in a strand

C.A 6681 E:

Transmitted signal frequency: 125 kHz
Large LCD screen
External voltage measurement: 12..600 VDC / AC (50..60 Hz)

C.A 6681 R:

Detection depth:
Single-pole: 0 to 2 m approximately
Two-pole application: 0 to 0.5 m approximately
Simple looping line: up to 2.5 m
Identification of network voltage: 0 to 0.4 m approximately
Large LCD screen

Supplied with

C.A 6681E transmitter, C.A 6681R receiver, hard case, 1 set of red/black 4 mm isolated banana leads (straight
male / elbowed male), 1 set of 2 crocodile clips, 1 stake for earthing, 1 x 9 V battery, 6 x 1.5 V AAA batteries, 1 measurement adapter for B22 socket (bayonet), 1 adapter for E14 socket (screw-in), 1 mains socket adapter and 1 operating manual in 5 languages.

View all in Cable Tracers & Fuse Finders

Stock information temporarily unavailable.

Price on asking

Chauvin Arnoux Cable Detector Cable Tracer, Cable Detection Depth 2.5m, 2.5 m 125 kHz, Maximum Safe Working Voltage 600

Price on asking

Chauvin Arnoux Cable Detector Cable Tracer, Cable Detection Depth 2.5m, 2.5 m 125 kHz, Maximum Safe Working Voltage 600

Stock information temporarily unavailable.

Technical Document

Specifications

Display Type

LCD, LCD

Product Type

Cable Detector

Cable Detection Depth

2.5, 2.5m

Meter Type

Cable Tracer

Battery Type

AAA, AAA

Power Source

Battery, Battery

Includes

Adapter, Battery, Carrying Case

Maximum Frequency

125kHz

Maximum Operating Temperature

40°C

Maximum Safe Working Voltage

600V

Standards/Approvals

No

Minimum Operating Temperature

40°C

Minimum Safe Working Voltage

12V

Safety Category Level

CAT III, CAT III

Safety Category Voltage

300, 300V

Country of Origin

Hong Kong

Product details

C.A 6681 LOCAT-N Cable Locator

The CA 6681 cable and metal-pipe detector is ideal for housing renovation, building maintenance and operations after incidents

Electricity:

The C.A 6681 LOCAT-N Cable Locator is simple to use on both current-carrying and non-current-carrying mains circuits. Its digital technology overcomes interference and disturbance signals to provide precise location details. The receiver displays the value of the signal measured, which is also shown on the bar chart or in the form of acoustic signals whose amplitudes vary in proportion to the signal distance.

Identify a fuse, circuit-breaker, etc.
Track a cable in a wall
Determine the location of a cut in the circuit
Locate short-circuits
Locate cable ducts in a house
Detect buried conductors

Plumbing / heating:

Locate pipes (copper, steel)
Track plastic pipes

Telecom:

Cable location
Identification of a pair in a strand

C.A 6681 E:

Transmitted signal frequency: 125 kHz
Large LCD screen
External voltage measurement: 12..600 VDC / AC (50..60 Hz)

C.A 6681 R:

Detection depth:
Single-pole: 0 to 2 m approximately
Two-pole application: 0 to 0.5 m approximately
Simple looping line: up to 2.5 m
Identification of network voltage: 0 to 0.4 m approximately
Large LCD screen

Supplied with

C.A 6681E transmitter, C.A 6681R receiver, hard case, 1 set of red/black 4 mm isolated banana leads (straight
male / elbowed male), 1 set of 2 crocodile clips, 1 stake for earthing, 1 x 9 V battery, 6 x 1.5 V AAA batteries, 1 measurement adapter for B22 socket (bayonet), 1 adapter for E14 socket (screw-in), 1 mains socket adapter and 1 operating manual in 5 languages.