ABB B7 B Contactor, 240 V ac Coil, 3-Pole, 9 A, 5.5 kW, 3NO, 690 V ac

RS Stock No.: 455-6333Brand: ABBManufacturers Part No.: GJL1311901R8010
brand-logo
View all in Contactors

Technical Document

Specifications

Brand

ABB

Coil Voltage

240 V ac

Number of Poles

3

Contact Voltage Rating

690 V ac

Contact Current Rating

9 A

Range

B7

Series

B

Power Rating

5.5 kW

Normal State Configuration

3NO

Number Of Auxiliary Contacts

1

Terminal Type

Screw

Length

57.5mm

Width

96.5mm

Depth

46.5mm

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

+55°C

Country of Origin

Germany

Product details

VB6/VB7 - Compact Rreversing Contactors

The mechanical lock between the two contactors prevents one of the contactors from switching on, as long as the other is still switched on and vice versa.
Switching over reversing contactors too quickly poses the risk of a phase short circuit.
This is the case if the arc of the contactor switching off has not yet extinguished and the contacts of the contactor switching on are already closed.
To avoid this risk, the two contactor coils must be switched to idle for a minimum of 50 ms during the switchover process and electrically locked against each other.

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

€ 82.23

Each (Exc. Vat)

ABB B7 B Contactor, 240 V ac Coil, 3-Pole, 9 A, 5.5 kW, 3NO, 690 V ac

€ 82.23

Each (Exc. Vat)

ABB B7 B Contactor, 240 V ac Coil, 3-Pole, 9 A, 5.5 kW, 3NO, 690 V ac
Stock information temporarily unavailable.

Buy in bulk

QuantityUnit price
1 - 4€ 82.23
5 - 9€ 78.12
10 - 24€ 74.00
25 - 49€ 69.89
50+€ 65.79

Technical Document

Specifications

Brand

ABB

Coil Voltage

240 V ac

Number of Poles

3

Contact Voltage Rating

690 V ac

Contact Current Rating

9 A

Range

B7

Series

B

Power Rating

5.5 kW

Normal State Configuration

3NO

Number Of Auxiliary Contacts

1

Terminal Type

Screw

Length

57.5mm

Width

96.5mm

Depth

46.5mm

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

+55°C

Country of Origin

Germany

Product details

VB6/VB7 - Compact Rreversing Contactors

The mechanical lock between the two contactors prevents one of the contactors from switching on, as long as the other is still switched on and vice versa.
Switching over reversing contactors too quickly poses the risk of a phase short circuit.
This is the case if the arc of the contactor switching off has not yet extinguished and the contacts of the contactor switching on are already closed.
To avoid this risk, the two contactor coils must be switched to idle for a minimum of 50 ms during the switchover process and electrically locked against each other.