Technical Document
Specifications
Brand
FlukeModel Number p
1503
Tester Type
Insulation Tester
Minimum Test Voltage
500V
Maximum Test Voltage
1000V
Maximum Insulation Resistance Measurement
2GΩ
Display Type
Backlit LCD
Calibrated
RSCAL
Test Current
200mA
Power Source
Battery
Battery Type
AA
Minimum Operating Temperature
-20°C
Maximum Operating Temperature
+55°C
Safety Category Level
CAT III, CAT IV
Safety Category Voltage
600V
Safety Category
CAT III 600 V, CAT IV 600V
Width
100mm
Length
203mm
Dimensions
203 x 100 x 50mm
Height
50mm
Weight
550g
Country of Origin
United States
Product details
Fluke 1500 Series Electrical Insulation Testers
Fluke 1507 (10 GΩ) and 1503 (2 GΩ) electrical insulation testers are compact, rugged, reliable and easy-to-use. Their multiple test voltages make them instruments of choice for troubleshooting, commissioning and preventative maintenance applications. The remote probe helps save time and money when performing tests.
Features & Benefits
Insulation test range 0.01 MΩ to 10 GΩ (1507), 0.1 MΩ to 2 GΩ (1503)Insulation test voltages 500 V, 1000 V (1503 only), 50 V, 100 V, 250 V (both models)Automatic calculation of Polarisation Index and Dielectric Absorption Ratio (1507)Compare (Pass/Fail) function (1507)Repetitive or hard-to-reach testing easy with the remote test probeFor added user protection, live circuit detection prevents insulation test if voltage > 30 V is detected Auto-discharge of capacitive voltage for added user protectionAC/DC voltage 0.1 V to 600 V200 mA continuityResistance 0.01 Ω to 20.00 kΩAuto power offLarge, backlit displayCAT IV 600 V overvoltage category ratingRemote probe, test leads, probes and alligator clips included with each testerAccepts optional Fluke TPAK magnetic hanging systemFour AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation te
Supplied with
Remote probe, test leads, test probes, alligator clips, holster, user documentation
Stock information temporarily unavailable.
Please check again later.
€ 635.59
Each (Exc. VAT)
Calibration type
RS Calibration
1
€ 635.59
Each (Exc. VAT)
Calibration type
RS Calibration
1
Technical Document
Specifications
Brand
FlukeModel Number p
1503
Tester Type
Insulation Tester
Minimum Test Voltage
500V
Maximum Test Voltage
1000V
Maximum Insulation Resistance Measurement
2GΩ
Display Type
Backlit LCD
Calibrated
RSCAL
Test Current
200mA
Power Source
Battery
Battery Type
AA
Minimum Operating Temperature
-20°C
Maximum Operating Temperature
+55°C
Safety Category Level
CAT III, CAT IV
Safety Category Voltage
600V
Safety Category
CAT III 600 V, CAT IV 600V
Width
100mm
Length
203mm
Dimensions
203 x 100 x 50mm
Height
50mm
Weight
550g
Country of Origin
United States
Product details
Fluke 1500 Series Electrical Insulation Testers
Fluke 1507 (10 GΩ) and 1503 (2 GΩ) electrical insulation testers are compact, rugged, reliable and easy-to-use. Their multiple test voltages make them instruments of choice for troubleshooting, commissioning and preventative maintenance applications. The remote probe helps save time and money when performing tests.
Features & Benefits
Insulation test range 0.01 MΩ to 10 GΩ (1507), 0.1 MΩ to 2 GΩ (1503)Insulation test voltages 500 V, 1000 V (1503 only), 50 V, 100 V, 250 V (both models)Automatic calculation of Polarisation Index and Dielectric Absorption Ratio (1507)Compare (Pass/Fail) function (1507)Repetitive or hard-to-reach testing easy with the remote test probeFor added user protection, live circuit detection prevents insulation test if voltage > 30 V is detected Auto-discharge of capacitive voltage for added user protectionAC/DC voltage 0.1 V to 600 V200 mA continuityResistance 0.01 Ω to 20.00 kΩAuto power offLarge, backlit displayCAT IV 600 V overvoltage category ratingRemote probe, test leads, probes and alligator clips included with each testerAccepts optional Fluke TPAK magnetic hanging systemFour AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation te
Supplied with