Technical Document
Specifications
Brand
BrandenburgOutput Voltage
0 → 2kV
Input Voltage Range
22 → 28 V dc
Power Rating
2W
Input Voltage Nominal
24 V dc
Output Current
1mA
Mounting Type
Screw Mount
Isolated
No
Number of Outputs
1
Depth
15mm
Width
49mm
Length
95.2mm
Series
4479
Load Regulation
500ppm
Minimum Temperature
-10°C
Maximum Temperature
+50°C
Country of Origin
United Kingdom
Product details
Brandenburg 2W High Voltage Regulated Non-Isolated DC-DC Converter, Photomultiplier Module - 4479 Series
12V or 24V input voltage
Positive or negative options
Non-isolated
Buffered output voltage & current monitors
Internal precision reference
Remote output programming
Demonstrated MTBF >1 million hours
Chassis mounting style with input connectors and fly lead output
Input protected against reverse polarity, output short circuit and flash over proof
Typical ripple, peak to peak: 1mV
Typical noise, peak to peak: 4mV
Supplied with
Input mating connectors
Approvals
UL recognised, CSA
Standards
UL1950
Stock information temporarily unavailable.
Please check again later.
P.O.A.
1
P.O.A.
1
Technical Document
Specifications
Brand
BrandenburgOutput Voltage
0 → 2kV
Input Voltage Range
22 → 28 V dc
Power Rating
2W
Input Voltage Nominal
24 V dc
Output Current
1mA
Mounting Type
Screw Mount
Isolated
No
Number of Outputs
1
Depth
15mm
Width
49mm
Length
95.2mm
Series
4479
Load Regulation
500ppm
Minimum Temperature
-10°C
Maximum Temperature
+50°C
Country of Origin
United Kingdom
Product details
Brandenburg 2W High Voltage Regulated Non-Isolated DC-DC Converter, Photomultiplier Module - 4479 Series
12V or 24V input voltage
Positive or negative options
Non-isolated
Buffered output voltage & current monitors
Internal precision reference
Remote output programming
Demonstrated MTBF >1 million hours
Chassis mounting style with input connectors and fly lead output
Input protected against reverse polarity, output short circuit and flash over proof
Typical ripple, peak to peak: 1mV
Typical noise, peak to peak: 4mV
Supplied with
Input mating connectors
Approvals
UL recognised, CSA
Standards
UL1950