Documentos Técnicos
Especificaciones
Brand
MeggerTipo de Comprobador
Pass/Fail PAT
Tipo de Prueba
Clase I, Clase II
Método de Prueba
Automatic, Manual
Descarga
Yes
Fuente de alimentación
Mains
Dimensiones del Cuerpo
330 x 375 x 200mm
Peso
6kg
Altura
200mm
Longitud
330mm
Temperatura Máxima de Operación
+40°C
Tensión Máxima de Alimentación
230V
Profundidad
375mm
Tensión Mínima de Alimentación
110V
Temperatura de Funcionamiento Mínima
0°C
Número de Modelo p
PAT4DV
Datos del producto
PAT4DV & PAT4DVF Dual Voltage Testers
These microprocessor controlled instruments are designed for maximum flexibility coupled with ease of use. They carry out routine safety tests on both 110V and 230V portable appliances and extension leads. The LCD display shows full details of clients and appliances which have been uploaded from data storage and which can be downloaded subsequently to a PC for certification and storage.
Circuit test checks appliance is not open circuit or short circuit
Earth Continuity test in accordance with EEA recommendations for IT Equipment
Insulation test at 500V d.c., into 0.5MΩ load or greater with user settable pass bands
Earth Leakage test measures earth leakage via differential method to cover multiple earth paths
Fuse Test to check for blown fuses
Flash test (ON DVF ONLY)
Visual checks
Stores up to 1000 test results with full client and asset details including descriptions for download to a PC
Full details can be uploaded from PC storage for on site history during retest
Alphanumeric keypad
Serial connection for PC and serial printer
Parallel printer connection
Información de stock no disponible temporalmente.
Vuelva a verificar más tarde.
P.O.A.
1
P.O.A.
1
Documentos Técnicos
Especificaciones
Brand
MeggerTipo de Comprobador
Pass/Fail PAT
Tipo de Prueba
Clase I, Clase II
Método de Prueba
Automatic, Manual
Descarga
Yes
Fuente de alimentación
Mains
Dimensiones del Cuerpo
330 x 375 x 200mm
Peso
6kg
Altura
200mm
Longitud
330mm
Temperatura Máxima de Operación
+40°C
Tensión Máxima de Alimentación
230V
Profundidad
375mm
Tensión Mínima de Alimentación
110V
Temperatura de Funcionamiento Mínima
0°C
Número de Modelo p
PAT4DV
Datos del producto
PAT4DV & PAT4DVF Dual Voltage Testers
These microprocessor controlled instruments are designed for maximum flexibility coupled with ease of use. They carry out routine safety tests on both 110V and 230V portable appliances and extension leads. The LCD display shows full details of clients and appliances which have been uploaded from data storage and which can be downloaded subsequently to a PC for certification and storage.
Circuit test checks appliance is not open circuit or short circuit
Earth Continuity test in accordance with EEA recommendations for IT Equipment
Insulation test at 500V d.c., into 0.5MΩ load or greater with user settable pass bands
Earth Leakage test measures earth leakage via differential method to cover multiple earth paths
Fuse Test to check for blown fuses
Flash test (ON DVF ONLY)
Visual checks
Stores up to 1000 test results with full client and asset details including descriptions for download to a PC
Full details can be uploaded from PC storage for on site history during retest
Alphanumeric keypad
Serial connection for PC and serial printer