Documentos Técnicos
Especificaciones
Brand
VCCÍndice de Tensión
10 V
Casquillo de la Lámpara
Terminal de cable
Valor Nominal de Corriente
27 mA
Diámetro
3mm
Tamaño de la Lámpara
T-1
Vida Útil
10000h
País de Origen
Taiwan, Province Of China
Datos del producto
Con pines de conexión T-1 (3 mm)
Gama de indicadores de filamento con extremo de cable T-1 (3 mm), específicamente diseñados para la iluminación de espacios confinados como medidores, interruptores, etc.
Wire-Ended & Bi-Pin
Filament lamps will perform to specification and give optimum life when:,a) They are powered at the rated voltage from a stabilised 50Hz ac supply,b) Ambient temperature is in the range 20 to 25°C,c) No mechanical vibration is present.,Deviations from these criteria can have a significant effect on lamp life, particularly with low current filaments (<80mA). Operation from a dc supply at rated voltage can reduce specified life by up to 50%. The effect of variation from the rated operating voltage should be noted: 5% above will reduce lamp life by up to 50%. 5% below will significantly increase lamp life. Current consumption can vary by up to ±10% on stated values at rated supply voltage. Care therefore should be exercised when running a number of lamps in series. In such applications it is recommended that the rated voltage be reduced by 10% to prevent premature failure of individual lamps.
Información de stock no disponible temporalmente.
Vuelva a verificar más tarde.
P.O.A.
50
P.O.A.
50
Documentos Técnicos
Especificaciones
Brand
VCCÍndice de Tensión
10 V
Casquillo de la Lámpara
Terminal de cable
Valor Nominal de Corriente
27 mA
Diámetro
3mm
Tamaño de la Lámpara
T-1
Vida Útil
10000h
País de Origen
Taiwan, Province Of China
Datos del producto
Con pines de conexión T-1 (3 mm)
Gama de indicadores de filamento con extremo de cable T-1 (3 mm), específicamente diseñados para la iluminación de espacios confinados como medidores, interruptores, etc.
Wire-Ended & Bi-Pin
Filament lamps will perform to specification and give optimum life when:,a) They are powered at the rated voltage from a stabilised 50Hz ac supply,b) Ambient temperature is in the range 20 to 25°C,c) No mechanical vibration is present.,Deviations from these criteria can have a significant effect on lamp life, particularly with low current filaments (<80mA). Operation from a dc supply at rated voltage can reduce specified life by up to 50%. The effect of variation from the rated operating voltage should be noted: 5% above will reduce lamp life by up to 50%. 5% below will significantly increase lamp life. Current consumption can vary by up to ±10% on stated values at rated supply voltage. Care therefore should be exercised when running a number of lamps in series. In such applications it is recommended that the rated voltage be reduced by 10% to prevent premature failure of individual lamps.