Documentos Técnicos
Especificaciones
Brand
Sensata / Cynergy3Tipo de Dispositivo
Float
Tipo de Montaje
Vertical
Salida del Interruptor
Carga Directa
Material de Cuerpo
Stainless Steel
Longitud de cable
350mm
Temperatura Mínima de Funcionamiento
-10°C
Temperatura de Funcionamiento Máxima
+120°C
Tensión AC Máxima
300V
Tensión DC Máxima
300V
Corriente Máxima
500 mA
Presión Máxima
40bar
Series
SSF28
Corriente Nominal
500 mA
País de Origen
Japan
Datos del producto
Stainless Steel High Pressure Float Switch – Vertical Mount
SSF28 series float switch has been designed to work at high pressures and can be vertically mounted within the tank.
Warning
The Cable entry point must NOT under any circumstances be submerged.
On the Horizontal switches they must be fitted through the wall of a tank so that the cable is on the outside.
On the vertical type the mounting thread and cable entry must be above the highest level of the liquid.
Información de stock no disponible temporalmente.
Vuelva a verificar más tarde.
€ 140,92
Each (Sin IVA)
1
€ 140,92
Each (Sin IVA)
1
Comprar en grandes cantidades
Cantidad | Precio Unitario sin IVA |
---|---|
1 - 4 | € 140,92 |
5 - 9 | € 136,55 |
10+ | € 132,18 |
Documentos Técnicos
Especificaciones
Brand
Sensata / Cynergy3Tipo de Dispositivo
Float
Tipo de Montaje
Vertical
Salida del Interruptor
Carga Directa
Material de Cuerpo
Stainless Steel
Longitud de cable
350mm
Temperatura Mínima de Funcionamiento
-10°C
Temperatura de Funcionamiento Máxima
+120°C
Tensión AC Máxima
300V
Tensión DC Máxima
300V
Corriente Máxima
500 mA
Presión Máxima
40bar
Series
SSF28
Corriente Nominal
500 mA
País de Origen
Japan
Datos del producto
Stainless Steel High Pressure Float Switch – Vertical Mount
SSF28 series float switch has been designed to work at high pressures and can be vertically mounted within the tank.
Warning
The Cable entry point must NOT under any circumstances be submerged.
On the Horizontal switches they must be fitted through the wall of a tank so that the cable is on the outside.
On the vertical type the mounting thread and cable entry must be above the highest level of the liquid.