Comprobador de protector de transitorios portátil Dehn LifeCheck
Portable device with LifeCheck sensor for flexible use. Fast and easy testing of LifeCheck-equipped arresters. LEDs indicate the status, charge of battery and the result of the LifeCheck test. The DRC LC M1+ features a snap-on LifeCheck sensor
Para comprobar rápidamente protectores equipados con LifeCheck
Dispositivo portátil, fácil de transportar y usar
Adaptador específico del país para unidad de carga
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
Información de stock no disponible temporalmente.
Vuelva a verificar más tarde.
€ 0,131
Each (In a Pack of 100) (Sin IVA)
100
€ 0,131
Each (In a Pack of 100) (Sin IVA)
100
Documentos Técnicos
Especificaciones
Datos del producto
Comprobador de protector de transitorios portátil Dehn LifeCheck
Portable device with LifeCheck sensor for flexible use. Fast and easy testing of LifeCheck-equipped arresters. LEDs indicate the status, charge of battery and the result of the LifeCheck test. The DRC LC M1+ features a snap-on LifeCheck sensor
Para comprobar rápidamente protectores equipados con LifeCheck
Dispositivo portátil, fácil de transportar y usar
Adaptador específico del país para unidad de carga
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.