Technical Document
Specifications
Brand
FlukeBest Accuracy
±0.025 %
Absolute Maximum Current Measurement
24mA
Model Number p
705
Calibrated
RSCAL
Resolution
0.001 mA
Safety Category
CSA C22.2
Battery Type
9 V
Battery Life
18 h
Power Source
Battery
Weight
350g
Height
164mm
Length
47mm
Maximum Operating Temperature
+55°C
Minimum Operating Temperature
-10°C
Safety Category Voltage
30V
Width
75mm
Country of Origin
United States
Product details
Fluke 705 Loop Calibrator
Fluke's integrated solution for calibration, maintenance of milliamp loops and repair, the 705 current loop calibrator is an ideal cost-effective source and measurement tool.
Delivering a mA accuracy of 0.02% it also provides quick and easy readings due to the simultaneous % and mA display. For 0 to 20 mA or 4 to 20 mA current loop testing and dc voltage from 0 to 28 V, it is supplied with a set of TL75 test leads (726-3624) and alligator clips.
Features and Benefits:
0.02% accuracy
24 V loop supply with mA measure
Simultaneous mA and % of span display
Selectable step/ramp outputs
mA sourcing, simulation and measurement
Compact case and protective holster
Quick battery replacement
FAQ's
What is a current loop calibrator?
Current loop calibrators are specially designed instruments for current loop trouble shooting, testing and calibration. They can source current on unpowered devices in a loop, simulate the operation of loop powered transmitters and also measure current. These calibrators often feature time saving technology, specialist graphics using digital interfaces and micro-processor based electronics.
How much current flows in each loop of a parallel circuit?
Determined by Ohm's law, which states that the current between 2 points through a conductor is directly proportionate to the voltage across those 2 points, divided by the resistance of the conductor. I = V/R. This is also the case for series and parallel circuits, however in parallel circuits the total current can be affected by the way the resistors have been connected, as well as their ohmic value. Current does divide up and there can be more current in one area over another nonetheless when all areas are added up the total amount is the same.
Supplied with
9V installed alkaline battery, AC70A alligator clips, C10 protective yellow holster Flex-Stand™, instruction sheet, TL75 safety-designed test lead set, NIST- traceable calibration report and data
Stock information temporarily unavailable.
Please check again later.
€ 1,138.55
Each (Exc. VAT)
Calibration type
RS Calibration
1
€ 1,138.55
Each (Exc. VAT)
Calibration type
RS Calibration
1
Technical Document
Specifications
Brand
FlukeBest Accuracy
±0.025 %
Absolute Maximum Current Measurement
24mA
Model Number p
705
Calibrated
RSCAL
Resolution
0.001 mA
Safety Category
CSA C22.2
Battery Type
9 V
Battery Life
18 h
Power Source
Battery
Weight
350g
Height
164mm
Length
47mm
Maximum Operating Temperature
+55°C
Minimum Operating Temperature
-10°C
Safety Category Voltage
30V
Width
75mm
Country of Origin
United States
Product details
Fluke 705 Loop Calibrator
Fluke's integrated solution for calibration, maintenance of milliamp loops and repair, the 705 current loop calibrator is an ideal cost-effective source and measurement tool.
Delivering a mA accuracy of 0.02% it also provides quick and easy readings due to the simultaneous % and mA display. For 0 to 20 mA or 4 to 20 mA current loop testing and dc voltage from 0 to 28 V, it is supplied with a set of TL75 test leads (726-3624) and alligator clips.
Features and Benefits:
0.02% accuracy
24 V loop supply with mA measure
Simultaneous mA and % of span display
Selectable step/ramp outputs
mA sourcing, simulation and measurement
Compact case and protective holster
Quick battery replacement
FAQ's
What is a current loop calibrator?
Current loop calibrators are specially designed instruments for current loop trouble shooting, testing and calibration. They can source current on unpowered devices in a loop, simulate the operation of loop powered transmitters and also measure current. These calibrators often feature time saving technology, specialist graphics using digital interfaces and micro-processor based electronics.
How much current flows in each loop of a parallel circuit?
Determined by Ohm's law, which states that the current between 2 points through a conductor is directly proportionate to the voltage across those 2 points, divided by the resistance of the conductor. I = V/R. This is also the case for series and parallel circuits, however in parallel circuits the total current can be affected by the way the resistors have been connected, as well as their ohmic value. Current does divide up and there can be more current in one area over another nonetheless when all areas are added up the total amount is the same.
Supplied with