Broyce Control Voltage Monitoring Relay, 1 Phase, SPDT, Maximum of 315 V, DIN Rail

RS Stock No.: 135-6187Brand: Broyce ControlManufacturers Part No.: LCVR/2 230V
brand-logo
View all in Monitoring Relays

Technical Document

Specifications

Monitoring Application

Voltage

Electrical Phase

1

Voltage Sensing Range

Maximum of 315 V

Contact Configuration

SPDT

Voltage Sensitivity

Overvoltage, Undervoltage

Mounting Type

DIN Rail

Phase Sensitivity

Single Phase

Time Delay

0.2 → 10s

Frequency Sensing Range

48 → 63Hz

Series

L

Dimensions

66.5 x 17.5 x 89mm

Maximum Voltage Sensed

315V

Terminal Type

Screw

Operating Temperature Range

+60°C

Minimum Operating Temperature

-20°C

Height

89mm

Width

17.5mm

Maximum Operating Temperature

+60°C

Length

66.5mm

Number of Poles

2

Special Features

Microprocessor Based, Monitors Own Supply And Detects If The Set Under Or Over Voltage Trip Levels Are Exceeded, Adjustments For Under And Over Voltage Trip Levels, Adjustment For Time Delay, Green Led Indication For Supply Status

Country of Origin

United Kingdom

Product details

LCVR/2 Under and Over Voltage plus Time Delay

Broyce Controls L-Series signal conditioners use a QR barcode marking method allowing direct access to all technical data sheets, ensuring correct information is always at your finger tips!

Features and Benefits

Compact 17.5 mm DIN Rail housing
Microprocessor based
True R.M.S. monitoring
Selectable nominal voltages to suit most popular single phase supply voltages
Monitors own supply and detects if the set Under or Over voltage trip levels are exceeded
Adjustments for Under and Over voltage trip levels
Adjustment for time delay
Independent relay outputs - Under voltage monitoring / Over voltage monitoring
2 x SPDT relay output 5A
Green LED indication for supply status
Red LED relay status indication

Approvals

UL Certification

Broyce Monitor Relays

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

€ 97.18

Each (Exc. Vat)

Broyce Control Voltage Monitoring Relay, 1 Phase, SPDT, Maximum of 315 V, DIN Rail

€ 97.18

Each (Exc. Vat)

Broyce Control Voltage Monitoring Relay, 1 Phase, SPDT, Maximum of 315 V, DIN Rail
Stock information temporarily unavailable.

Technical Document

Specifications

Monitoring Application

Voltage

Electrical Phase

1

Voltage Sensing Range

Maximum of 315 V

Contact Configuration

SPDT

Voltage Sensitivity

Overvoltage, Undervoltage

Mounting Type

DIN Rail

Phase Sensitivity

Single Phase

Time Delay

0.2 → 10s

Frequency Sensing Range

48 → 63Hz

Series

L

Dimensions

66.5 x 17.5 x 89mm

Maximum Voltage Sensed

315V

Terminal Type

Screw

Operating Temperature Range

+60°C

Minimum Operating Temperature

-20°C

Height

89mm

Width

17.5mm

Maximum Operating Temperature

+60°C

Length

66.5mm

Number of Poles

2

Special Features

Microprocessor Based, Monitors Own Supply And Detects If The Set Under Or Over Voltage Trip Levels Are Exceeded, Adjustments For Under And Over Voltage Trip Levels, Adjustment For Time Delay, Green Led Indication For Supply Status

Country of Origin

United Kingdom

Product details

LCVR/2 Under and Over Voltage plus Time Delay

Broyce Controls L-Series signal conditioners use a QR barcode marking method allowing direct access to all technical data sheets, ensuring correct information is always at your finger tips!

Features and Benefits

Compact 17.5 mm DIN Rail housing
Microprocessor based
True R.M.S. monitoring
Selectable nominal voltages to suit most popular single phase supply voltages
Monitors own supply and detects if the set Under or Over voltage trip levels are exceeded
Adjustments for Under and Over voltage trip levels
Adjustment for time delay
Independent relay outputs - Under voltage monitoring / Over voltage monitoring
2 x SPDT relay output 5A
Green LED indication for supply status
Red LED relay status indication

Approvals

UL Certification

Broyce Monitor Relays